Client: Drinks Manufacturer

Project Brief: The Internal Lining of 2 No. Stainless Steel, Cylindrical Water Retaining Structures

System Specification: Solvent Free Polyurethane

Completion Date: 24th September 2008

COVAC Contract Ref: 752

Summary of Works

2 No. stainless steel, cylindrical, water retaining structures located externally within the grounds of the new plant on the outskirts of the location. Each structure is sized at approximately 3.8m diameter x 4.1m high and are positioned fairly close to each other. The manway access is approximately 500mm long x 400mm high.

water tank before treatment water tank before treatment

Internal surfaces of the tanks prior to any work commencing.

water tank after abraisive blasting water tank after abraisive blasting water tank after abraisive blasting water tank after abraisive blasting

The internal substrate of each Tank after being prepared by COVAC Operatives utilizing dry abrasive blasting equipment in accordance with Swedish Standard SA 2.5 BS7079 Part A1 1989.

water tank after a coat of solvent free polyurethane water tank after a coat of solvent free polyurethane water tank after a coat of solvent free polyurethane water tank after a coat of solvent free polyurethane

All seams and intricate areas were initially ‘stripe coated’ prior to the first full coat. Here the substrates receive the 1st full coat of Solvent Free Polyurethane.

water tank stripe coated water tank stripe coated water tank stripe coated water tank stripe coated

All intricate areas were again ‘stripe coated’ for a second time. The following photographs show the final application of the 2nd coat of Solvent Free Polyurethane.

polyurethane coated tank polyurethane coated tank

Call us today find out why you should use our alternative to water tank replacement on: 0800 772 3367.